    My recently acquired 99 fires up after two rounds of priming, but very weakly. One possibility (or so I'm guessing) is that a poor seal on the filler cap is preventing it from building up much in the way of pressure. Or could the weak flame be a symptom of the wick being scorched or otherwise not up to snuff? I will be replacing the cap gasket in any case, but wondering how likely that is to be the source of the problem.

    One other thing that has me a bit puzzled is the amount of rotation, or lack of it, in the control valve. The full operating range--from the fully clockwise "off" position to the fully counterclockwise position, with the cleaning needle visibly protruding from the jet--is less than a half-turn of the key. I'd estimate that the total range is 150 degrees or so. I would have expected it to be similar to the range of motion I'm familiar with from my Svea 123, which is around two full turns, I think. Or is this normal for a 99? This is the first one I've encountered.

    Given that everyone here already knows what a 99 looks like, I'm not attaching a photo for now. But if that would somehow be useful, let me know and I would be happy to do so.
     
  2. hikerduane

    hikerduane Subscriber

    Offline
    Joined:
    Mar 1, 2010
    Messages:
    10,865
    Location:
    Plumas County, CA
    Easy to check pressure loss from the cap.
    Empty fuel.
    Place stove in freezer with cap loose.
    Leave for 10 or 15 minutes.
    Remove from freezer, tighten cap very good.
    Dunk tank in hot water so as you can see if cap leaks.
    Easy.
    Duane
     
  3. Lennart F

    Lennart F Sweden Subscriber

    Offline
    Joined:
    Jun 24, 2017
    Messages:
    1,250
    Location:
    Vänersborg, Sweden
    First suspect is filler cap seal, second suspect is the seal in the safety release valve(SRV) in the filler cap - both seals are easy to replace and easy to make from fuel resitant rubber sheet if needed.
    There are no other obvious suspects for that problem.
     
  4. Jon Vara

    Jon Vara United States Subscriber

    Offline
    Joined:
    Jun 4, 2025
    Messages:
    65
    Location:
    Cabot, Vermont, USA
    Simple problems have simple solutions, suggesting that this may not be a simple problem. Tried the stove again with a cap from my Svea 123, which is known to hold pressure, and got the same result: Double priming yields a very weak flame. Not sure where to go from here.

    I know, I should do a dunk test but I am evidently too lazy. What would that tell me that switching caps did not?
     
  5. Lennart F

    Lennart F Sweden Subscriber

    Offline
    Joined:
    Jun 24, 2017
    Messages:
    1,250
    Location:
    Vänersborg, Sweden
    Ok - I didn't really think about valve/needle as a possible problem, but one possible issue is wrong needle or needle position - I don't know about the burners on 123R/8R/99 but other burners of similar valve design usually operates with 180+ degrees from closed to full pricking, using first 1/4-1/3 turn for regulating before the needle enter the jet.
    You could take off the burner bell, warm the tank slightly to get some pressure and(outdoors in safe area) open the valve to check the fuel stream visually. I guess you need to lower the needle one step - close valve, unscrew jet, slowly open valve with slight push on needle until you feel the click, close valve and fit jet+bell - check that the valve close fully first cold, then hot and then after several minutes at full power - too low needle would stop valve before it close fully, most leak with hot burner.
     
  6. Jack Tar

    Jack Tar Germany Subscriber

    Offline
    Joined:
    Jun 6, 2025
    Messages:
    30
    Location:
    Germany
    If the gasket in the 123 cap is already a bit hardened, it could be shaped or deformed by the 123 filling neck.
    Then it is able to hold pressure on the 123, but might leak on the 99.
    Be sure, that the rubber is still soft to form a good seal.

    Dunk test recommended, just to ensure a proper seal.
    Leaking or hardened rubber seals can be very subtle.
     
    Last edited: Aug 25, 2026 at 6:33 PM
  7. ROBBO55

    ROBBO55 Subscriber

    Offline
    Joined:
    Oct 27, 2014
    Messages:
    2,702
    Location:
    Somersby, New South Wales, Australia
    If the cap seals are good, remove the cleaning needle rack and try lighting again. While it's out check for carbon buildup.

    To reset the rack they have to be set to about 4 or 5 clicks.
    With the regulator key/knob turned fully to the closed position, place the needle on to the cogs and slighty push down on the needle i use a pencil with a eraser on the end,and slightly turn the key to the open position to you hear it click down on 4 or 5 cogs,sometimes 6 is needed.
    If you look in the instructions gallery there is instructions on this prcedure
     
  8. afoton

    Offline
    Joined:
    Jan 17, 2014
    Messages:
    584
    When doing the dunk test, open the regulator to check that there are no blockage.
    Do the same dunk test with your Svea 123 to compare.
     
  9. Jon Vara

    Jon Vara United States Subscriber

    Offline
    Joined:
    Jun 4, 2025
    Messages:
    65
    Location:
    Cabot, Vermont, USA
    I'm fairly new here, and don't know my way around the site very well. What is this "instructions gallery?" you mention. I can't find any reference to it. Similarly, I don't know anything about the cleaning needle rack. I understand that it must be the mechanism that controls the cleaning needle, bit it's a black box to me. I'm a little hesitant to dismantle the valve and hope I'll be able to puzzle things out once I have it apart.
     
  10. snwcmpr

    snwcmpr SotM Winner Subscriber

    Offline
    Joined:
    Nov 16, 2011
    Messages:
    22,077
    Location:
    North Carolina
    In the library
    Instructions will not cover dunk test

    Screenshot_20260826-083058_DuckDuckGo.jpg Screenshot_20260826-083112_DuckDuckGo.jpg
     
  11. Jon Vara

    Jon Vara United States Subscriber

    Offline
    Joined:
    Jun 4, 2025
    Messages:
    65
    Location:
    Cabot, Vermont, USA
    Useful to know, thanks! Is there any way to search the library for any specific articles on resetting the cleaning needle, other than randomly scrolling around? I get nowhere using the main search box for the site. There's nothing relevant under "reset rack needle optimus," for example.

    I'm pretty good at actually repairing stuff, but it seems that my information-finding skills are well short of what's needed here.
     
  12. William Ritchie

    Offline
    Joined:
    Aug 3, 2015
    Messages:
    299
    Location:
    San Diego California USA


    Short tutorial hope this helps , it is a 123R shown but same method , needle may look a little different in the 99 .
     
  13. Jon Vara

    Jon Vara United States Subscriber

    Offline
    Joined:
    Jun 4, 2025
    Messages:
    65
    Location:
    Cabot, Vermont, USA
    Great, thank you, that looks promising--I will have a look.

    For what it's worth, a dunk test with the original cap revealed no leakage.