Optimus Pump Caps

Diskussion i 'Stove Forum' startad av Schwert, 30 augusti 2013.

  1. Schwert

    Offline
    Blev medlem:
    9 augusti 2013
    Inlägg:
    63
    Aktopp back in 2007 has about the clearest info I have found on the internal workings of the Optimus Pump Cap.

    These two images were like a beam of light revealing the simple and brilliant engineering that incorporates both an NRV and SRV into the cap.

    (I have taken the liberty to take his images from photobucket and put them into this post via the image uploader rather than using his original photbucket links )

    1377823075-aktopp_cap_1.jpg

    1377823097-aktopp_cap_4.jpg


    The thread where aktopp posted these is here:

    https://classiccampstoves.com/threads/5518

    That thread has some back-and-forth discussion about the safety of repairing the pump cap vs just replacing it.

    So are “new” caps actually NEW?

    If one orders a replacement pump cap does it have seals from 1970+ or are they new--say to this decade?

    It seems that replacing the NRV seal would not only be safe but prudent in an old cap. Replacing the o-ring SRV may or may not depending upon the strength of the spring….but if one just put a 1970 unfired pump cap on their stove is it actually any safer then replacing both seals in your old cap?
     
    Last edited by a moderator: 2 juli 2015
  2. Schwert

    Offline
    Blev medlem:
    9 augusti 2013
    Inlägg:
    63
    Last edited by a moderator: 2 juli 2015
  3. theyellowdog

    Offline
    Blev medlem:
    10 mars 2008
    Inlägg:
    2.104
    Last edited by a moderator: 1 juli 2015
  4. presscall

    presscall United Kingdom PotY Winner SotM Winner SotY Winner Subscriber

    Offline
    Blev medlem:
    25 augusti 2009
    Inlägg:
    13.956
    Från:
    Lancashire, United Kingdom
    Last edited by a moderator: 1 juli 2015
  5. Schwert

    Offline
    Blev medlem:
    9 augusti 2013
    Inlägg:
    63
    Yes, John that is an excellent post.

    So does anyone actually know the age of "NEW" pump caps?

    It seems that refitting the seals in these old caps would be a much more prudent idea than trusting that some "New" cap that is 3 decades old would somehow be a better or a safer choice.
     
  6. presscall

    presscall United Kingdom PotY Winner SotM Winner SotY Winner Subscriber

    Offline
    Blev medlem:
    25 augusti 2009
    Inlägg:
    13.956
    Från:
    Lancashire, United Kingdom
    I'd say the most recent of Swedish manufacture would be 70's at a guess. Oriental clones of a Svea/Optimus 123 might produce newer examples of a cap/SRV ensemble.

    So, not exactly new then and 'unused' doesn't really count when the material that degrades (the nitrile seal) is susceptible to shelf life and not just the heat and pressure when in use on a stove.

    John
     
  7. Schwert

    Offline
    Blev medlem:
    9 augusti 2013
    Inlägg:
    63
    I think I will try grinding a hex to penta...as I agree, reworking the SRV and NRV is a more prudent than betting on a 3+decade 'new' seal.

    Thanks John.